Fire Safety Equipment and the Fire-Code Compliance Notice for Inn Businesses: What to Check Before Applying

Illustration of a fire extinguisher, documents and a ryokan

Information as of 2026-11-23
Laws, local ordinances and statistics may change with amendments or new releases. For a specific property, please check with the local authority or a specialist.

When you turn a house or a condominium unit into accommodation, fire safety is one of the parts that can take time to prepare. The license under the Hotel Business Act (旅館業法) is handled by the public health center, but whether the building complies with fire laws and regulations is checked by the fire station. In this article, we go over the main fire safety equipment required at inn business properties and the basics of the "fire-code compliance notice" (消防法令適合通知書), which comes into play when you apply for the license.

Under the Fire Service Act, accommodation is treated as "ryokan, hotels and similar"

Guests who stay at accommodation aren't familiar with the building. They're asleep at night, and in a place they're visiting for the first time, it's hard to know where the emergency exits are. That's exactly why accommodation needs more safeguards than a regular home.

Under the Fire Service Act, the required equipment is set for each way a building is used (its "use"). The list of uses is in Appended Table 1 of the Order for Enforcement of the Fire Service Act, where ryokan, hotels, lodging houses and similar fall under item (5)(a) ((5)項イ). An ordinary apartment building is item (5)(b) ((5)項ロ), so even in the same building, what's required changes once it becomes accommodation.

The use is determined building by building by the local fire station. Start by confirming with the fire station: "As accommodation, which use would this property fall under?" We cover the overall steps to a license in How to Get a Ryokan (Inn) Business License in Japan.

Main fire safety equipment and when it's generally required

We've summarized the equipment that commonly applies to item (5)(a) buildings, based on the Order for Enforcement of the Fire Service Act and other rules.

Equipment Main rules Points to check
Fire extinguishers Required in buildings with a total floor area of 150㎡ or more. Also required on basement floors, windowless floors and floors on the 3rd story or above with a floor area of 50㎡ or more Even a small building may need them because of the floor conditions
Automatic fire alarm system Required regardless of total floor area Small facilities have the special provision explained below
Exit signs and guide lights Exit signs and corridor guide lights are installed They may not be needed in parts that meet the ministerial ordinance's conditions, such as when the exit can be seen clearly
Emergency lighting Required by the Building Standards Act in hotel and ryokan rooms and evacuation routes There are also exemption conditions, so check with an architect or the building department
Flame-retardant items Curtains, fabric blinds, blackout curtains, carpets and similar must be flame-retardant Choose flame-retardant products when replacing or adding items, too
Sprinkler system Buildings with 11 or more stories excluding basements, buildings with a total floor area of 6,000㎡ or more (excluding single-story buildings) and so on Mainly for large or tall buildings

A little more detail. Small facilities may be able to use an "automatic fire alarm system for specified small-scale facilities" (特定小規模施設用自動火災報知設備). If conditions such as a total floor area under 300㎡ are met, this equipment can be installed instead of a standard automatic fire alarm system (under a ministerial ordinance of the Ministry of Internal Affairs and Communications). According to the Fire and Disaster Management Agency's leaflet, there are also types that use battery-powered detectors linked wirelessly, and some need no wiring work. If you install detectors only, the work doesn't require a licensed fire protection equipment engineer, and no notification is needed before the work. However, you do need to file a notification after installation. Note that interconnected residential fire alarms can't be used in place of this equipment.

As for exit signs and guide lights, the Fire and Disaster Management Agency has also set out a special exception: when a building that was originally a detached house is turned into accommodation, they don't have to be installed if requirements such as easy evacuation are met. The requirements include posting an evacuation route map where guests can easily see it.

What matters next is the procedure after the equipment is installed. For item (5)(a) buildings, once fire protection equipment is installed, you notify the fire station and have it inspected (Article 17-3-2 of the Fire Service Act). Municipalities can also set rules by ordinance that differ from the national standards. Since what's required varies by area, check with the local fire station in the end.

What is a fire-code compliance notice? The steps to getting one

A "fire-code compliance notice" is a document issued by the fire station or a similar body showing that the building complies with fire laws and regulations. A Fire and Disaster Management Agency notice sets out the steps for issuing it as a document attached to applications such as a business license under the Hotel Business Act or a notification of changes to facilities and equipment. Whether and when you actually need to submit it, follow the public health center's guidance.

The general steps are as follows:

  1. Advance consultation with the fire station: Bring the floor plans and confirm the building's use and the equipment it needs.
  2. Construction and installation of equipment: Put the required equipment in place, file the installation notification and have it inspected.
  3. Applying for the notice: Fill in the application form with the facility's name, address and the reason for applying (such as a business license under the Hotel Business Act) and submit it.
  4. On-site inspection and similar checks: The fire authorities visit the site and check its compliance.
  5. Issuance: If the building complies, the notice is issued. If not, you're told that it can't be issued and why.

If corrections come up during construction, the license application is delayed by that much, too. You'll have peace of mind if you finish consulting the fire station before signing a contract for the property or at the design stage.

It continues after opening: fire prevention managers, inspections and reports

Fire safety doesn't end once you open.

First, the fire prevention manager. In item (5)(a) buildings, once the capacity (the number of people who come and go, work or live in the building) reaches 30 or more, a fire prevention manager must be appointed. The fire prevention manager draws up a fire prevention plan and, based on it, carries out firefighting, reporting and evacuation drills, inspects and maintains equipment, supervises the handling of fire and so on. When you appoint one, you need to notify the fire station. How the capacity is counted is set by ministerial ordinance, so check with the fire station.

Next, inspecting and reporting on fire protection equipment. The installed equipment must be inspected regularly, and the results reported to the fire station (Article 17-3-3 of the Fire Service Act). The inspection interval is set as a period of up to one year determined by the Commissioner of the Fire and Disaster Management Agency. The Agency's leaflet says that accommodation is inspected twice a year and reports are made once a year. Buildings with a total floor area of 1,000㎡ or more and similar are inspected by qualified people such as licensed fire protection equipment engineers. In other buildings, the people involved can also do the inspections themselves.

Putting the inspection dates in your calendar makes them easier to remember.

Points to note when starting in a condominium unit or apartment building

If you're thinking of running an inn business in a condominium unit, this part is especially important.

A Fire and Disaster Management Agency notice states that, for an apartment building with units that become accommodation, the use is determined for each unit and then for the building as a whole. The leaflet explains that, depending on factors such as the share of units used as accommodation, the whole building is treated as an "apartment building," a "mixed-use building (item (16)(a), (16)項イ)" or "accommodation (item (5)(a))."

In other words, even if you think it's only about one unit, it can affect the fire safety equipment of the whole building. For example, if the building becomes a mixed-use building and has a total floor area of 300㎡ or more, installing an automatic fire alarm system becomes a matter for the whole building (depending on the conditions, an automatic fire alarm system for specified small-scale facilities may be usable). The leaflet also says that you may be instructed to install detectors so that alarms sound in shared areas such as hallways. Since shared areas aren't something an individual can decide on, talking with the owners' association is essential.

Also, where the owner lives in the same home and rents out part of it, the home may be treated as a residence depending on the floor area of the guest rooms. Check with the fire station which case applies. For ward-by-ward points to check, including the condominium management rules, see also Opening Simple Lodging in Tokyo's 23 Wards.

A preparation checklist, and our approach at Alotz

Checking the following points before you decide on a property makes things go more smoothly:

  • The property's total floor area, number of stories, and whether it has basement floors or floors with few windows
  • Whether it's a detached house or a unit in an apartment building (and if it's an apartment building, what the use of the whole building will be)
  • The use determined by the fire station and the list of required equipment
  • Whether the automatic fire alarm system for specified small-scale facilities or the exit sign exception can be used
  • The views of an architect or the building department on emergency lighting
  • A plan to switch curtains and carpets to flame-retardant products
  • The schedule for installation notifications and inspections and for applying for the fire-code compliance notice
  • Whether the property is large enough to need a fire prevention manager, and who you'll ask to do the inspections

Designing, installing and inspecting fire safety equipment is work for specialists such as licensed fire protection equipment engineers. The properties we at Alotz manage are, as a rule, all licensed under the Hotel Business Act, and you're welcome to consult us about support toward opening, such as preparations related to the business license. We introduce operations after opening on our Property management and Ryokan management pages.

Summary

  • Ryokan, hotels and similar fall under item (5)(a) in Appended Table 1 of the Order for Enforcement of the Fire Service Act, and need more equipment than a regular home.
  • For item (5)(a), an automatic fire alarm system is required regardless of total floor area. Where the total floor area is under 300㎡ and other conditions are met, an automatic fire alarm system for specified small-scale facilities may be usable.
  • Fire extinguishers, exit signs and guide lights, emergency lighting, flame-retardant items and sprinkler systems may also be required depending on the building's size and structure.
  • The fire-code compliance notice is issued after an application to the fire station and checks such as an on-site inspection.
  • After opening, the fire prevention manager (for a capacity of 30 or more) and equipment inspections and reports continue.
  • In a condominium unit, the use of the whole building may change. Check with the fire station and the owners' association before signing a contract.

Even if you're at the stage of "I don't know whether this property can be used for an inn business, or what to check first," that's perfectly fine. Feel free to reach out via our Contact page.

Sources and references

  • e-Gov法令検索「消防法」 (e-Gov Laws and Regulations Search: Fire Service Act) https://laws.e-gov.go.jp/law/323AC1000000186
  • e-Gov法令検索「消防法施行令」 (e-Gov Laws and Regulations Search: Order for Enforcement of the Fire Service Act) https://laws.e-gov.go.jp/law/336CO0000000037
  • e-Gov法令検索「消防法施行規則」 (e-Gov Laws and Regulations Search: Regulation for Enforcement of the Fire Service Act) https://laws.e-gov.go.jp/law/336M50000008006
  • e-Gov法令検索「特定小規模施設における必要とされる防火安全性能を有する消防の用に供する設備等に関する省令」 (e-Gov Laws and Regulations Search: Ministerial Ordinance on fire protection equipment with the fire safety performance required for specified small-scale facilities) https://laws.e-gov.go.jp/law/420M60000008156
  • e-Gov法令検索「建築基準法」 (e-Gov Laws and Regulations Search: Building Standards Act) https://laws.e-gov.go.jp/law/325AC0000000201
  • e-Gov法令検索「建築基準法施行令」 (e-Gov Laws and Regulations Search: Order for Enforcement of the Building Standards Act) https://laws.e-gov.go.jp/law/325CO0000000338
  • 消防庁「防火対象物に係る表示制度の実施に伴う『旅館ホテル防火安全対策連絡協議会における了解事項』の運用について」(平成26年3月7日 消防予第60号) (Fire and Disaster Management Agency: On applying the "agreed matters of the Ryokan and Hotel Fire Safety Liaison Council" with the introduction of the fire safety mark system for buildings, Shoboyo No. 60, March 7, 2014) https://www.fdma.go.jp/laws/tutatsu/assets/260307_yo60.pdf
  • 消防庁「民泊における消防法令上の取り扱い等」 (Fire and Disaster Management Agency: How minpaku are handled under fire laws and regulations) https://www.fdma.go.jp/mission/prevention/suisin/post20.html
  • 消防庁「民泊における消防法令上の取扱い等に関するリーフレット(令和8年3月時点版)」 (Fire and Disaster Management Agency: Leaflet on how minpaku are handled under fire laws and regulations, as of March 2026) https://www.fdma.go.jp/mission/prevention/suisin/items/minpaku_leaf_horei_r803.pdf
  • 消防庁「住宅宿泊事業法に基づく届出住宅等に係る消防法令上の取扱いについて(通知)」(平成29年10月27日 消防予第330号) (Fire and Disaster Management Agency: Notice on how homes notified under the Private Lodging Business Act are handled under fire laws and regulations, Shoboyo No. 330, October 27, 2017) https://www.fdma.go.jp/mission/prevention/suisin/items/291027_yo330.pdf
  • 消防庁「一般住宅を宿泊施設や飲食店等に活用する場合における消防用設備等に係る消防法令の技術上の基準の特例の適用について(通知)」(平成29年3月23日 消防予第71号) (Fire and Disaster Management Agency: Notice on applying special exceptions to the technical standards for fire protection equipment when ordinary homes are used as accommodation, restaurants and similar, Shoboyo No. 71, March 23, 2017) https://www.fdma.go.jp/mission/prevention/suisin/items/290323_yo71.pdf